Sapphire Multi-Therapy Infusion Pump
With unique patented technology, innovative design, and an intuitive touch screen, the Sapphire infusion pump helps you deliver exceptional care.
- Reduce time spent starting an infusion
- Effortless set-up, programming, and readability
- Intuitive user interface for quick, easy programming
- Flexible drug library editor provides hard/soft limits and up to 1,000 drug profiles
- ISO/IEC 17025 Compliant for Air Ambulance Medical Transport
- Item IP16365 includes: Pump, Battery, Power Cord, and IFU via QR code on box.
***Please note: Items IP16353 (Sapphire Communication Cable) and IP16361 (RS232 Adapter) are required to program and service the Sapphire pump. Both are sold separately and are listed below.***
- 5.63"H x 3.78"W x 1.93"D
- Weight: 418g (without battery); 504g (with battery)
- Infusion Delivery Modes: Continuous (with/without a secondary line), PCA, Intermittent, Multi-step, TPN, Epidural (PCEA, Epidural Intermittent & PIEB)
- Infusion Pump: Volumetric, peristaltic
- Pumping Mechanism: Single channel volumetric, with integral pressure sensor
- Accuracy: ±2.5% (subject to external conditions such as tubing, pressure, container position relative to the Sapphire infusion pump, barometric pressure,
- humidity, and temperature)
- External Power Supply: 100-240V 50-60 Hz, 0.6A
- Adaptor: AC Adaptor 10 VDC/2.0A
- Rechargeable Li-ion battery 7.4V, 1960 mA/h 24 hrs @ 125 mL/h (with fully charged battery and backlight off)
- Recharge time: up to 6 hrs (when Sapphire infusion pump is not in operation)
- Fuse Rating: T1.6A, 250V
- Defibrillation Proof Recovery Time: Max 1 sec
- Volume (VTBI): 0.1–9999 mL in increments of 0.1 mL
- Flow Rate: 0.1–99.9 mL/h in increments of 0.1 mL/h; 100–999 mL/h in increments of 1 mL/h
- Priming: Manual or automatic priming (600 mL/h, or from air-in-line alarm 900 mL/h)
- KVO Rate: Up to 20 mL/h with increments of 0.1 mL/h
- Sensors: Air-in-line sensor: detects single and accumulated bubbles sized 0.02–0.5 mL. The desired size range of each option can be selected by the technician.
- Upstream/downstream occlusion sensor
- Door open sensor
- Temperature sensor
- Operating Temperature: +5oC (41oF) to 40oC (104oF)
- Alarms and Messages: Alarms: Air in Line, Cassette Misplaced, Occlusions, Check for Occlusion,
- Downstream Occlusion, Upstream Occlusion, Flow Error, Insufficient Battery
- Messages: Battery Issues (Low Battery, When Battery Life Will Expire, Battery Not Fully Charged), Annual Certification, Cassette Door Open, Infusion Status (Complete, Near End), Pump Inactive
- Standards Compliance: IEC 60601-1, UL 60601-1 and CAN/CSA C22.2 601.1-M90 medical electrical equipment, which classifies the Sapphire infusion pump as:
- Class II, Type BF, Continuous operation, IP24 dust and splash proof
- Not suitable for use in the presence of flammable anesthetic mixture with air or with oxygen or nitrous oxide
- IEC 60601-1-12: Requirements for medical electrical equipment and medical electrical systems intended for use in the emergency medical services environment
- IEC 60601-1-2, IEC 60601-2-24, IEC 60601-1-11, IEC 60601-1-8
- Defibrillator compliance statement: Equipment Type BF Applied Part. IEEE 802.11 a/b/g/n
Sapphire Multi-Therapy Infusion Pump Overview
Our product specialist, Forrest, shows us how the Sapphire Multi-Therapy Infusion Pump operates and the many advantages it provides.What is included in an order for the Sapphire™ Multi-Therapy Infusion Pump?
Anonymous- On Wednesday, 24 January 2018
Item number IP16365 (Sapphire™ Multi-Therapy Infusion Pump) comes with: Battery, Power Cord, & User Manual (via QR code). Other accessories (including Travel Case) are sold separately.
Sara K.- answered On Friday, 26 January 2018
I would like to demo one of the Sapphire™ Multi-Therapy Infusion Pump units before ordering. Is that possible?
Anonymous- On Friday, 31 May 2019
Yes, we can schedule a demo of the Sapphire™ Multi-Therapy Infusion Pump. Please contact our Customer Care team via phone (800-824-6016) or email [email protected] to get started.
Sara K.- answered On Sunday, 02 June 2019
Does the Sapphire™ Multi-Therapy Infusion Pump come with a service warranty?
Megan S.- On Tuesday, 16 July 2019
The Sapphire™ Multi-Therapy Infusion Pump has a two year warranty, beginning with the date of purchase.
Jeff S.- answered On Thursday, 18 July 2019
Does Q-Core Medical make a Syringe Pump version of the Sapphire Infusion Pump?
Anonymous- On Thursday, 02 September 2021
No, Q-Core Medical does not make a Syringe Pump version of the Sapphire Infusion Pump.
Forrest U.- answered On Saturday, 04 September 2021
Can I perform my own Preventative Maintenance on my Sapphire Multi-Therapy Infusion Pumps?
Anonymous- On Tuesday, 07 December 2021
Yes, in order to perform your own Preventative Maintenance on your Sapphire Infusion Pumps, you will need to have a Level 1 Certification. For more information regarding this Certification Process, please contact our Customer Care Team at 800-824-6016.
Forrest U.- answered On Thursday, 09 December 2021
What is the difference between Sapphire IV Administration Sets IV43301 & IV40901?
Anonymous- On Wednesday, 26 January 2022
IV43301 is an infusion set that is 113" with 1 needleless downstream Y-site. IV40901 is a primary infusion set the is 109" with a back check valve & 2 needleless Y-sites; 1 above & 1 downstream. For more information regarding IV administration set specifications, please see the Sapphire Multi-Therarpy Infusion Pump Accessory Catalog loacated in the "More Information" section on our website.
Forrest U.- answered On Thursday, 27 January 2022
What is the cost of the Ferno double and triple pump mounting brackets for the Sapphire Multi-Therapy Infusion Pump?
Anonymous- On Thursday, 15 September 2022
The part numbers for the Ferno mounting brackets for the Sapphire Multi-Therapy Infusion Pump are IP91140 double, and IP91145 triple. Please call our Customer Care department at 800-824-6016 for current pricing.
Jim L.- answered On Saturday, 17 September 2022
Does the Sapphire Infusion Pump allow for blood infusion?
Aaron R.- On Thursday, 11 July 2024
Yes, The Eitan Sapphire Multi-Therapy Infusion Pump is designed to infuse blood if appropriate blood infusion set is used.
Dave M.- answered On Thursday, 11 July 2024
What equipment is needed to perform annual preventative maintenance on a Sapphire Multi-Therapy Infusion Pump?
Anonymous- On Wednesday, 25 September 2024
To perform annual preventative maintenance on a Sapphire Multi-Therapy Infusion Pump, you will need the Pump, Level 1 Certification, FasTest Kit, Sapphire Splitter, Sapphire Communication Cable & Sapphire USB to 4-Port RS232 Adapter.
Forrest U.- answered On Wednesday, 25 September 2024